Question

What is the minimum shell thickness (t-min) on an existing tank?

For a welded tank shell, t-min is the thinnest a shell course may get and stay in service at its current fill height. API 653 clause 4.3.3.1 a) calculates it for a whole course from the diameter, the liquid height above the bottom of that course less one foot, the highest specific gravity of the contents, the allowable stress and the joint efficiency, and never lets it fall below a tenth of an inch for any course.

The method covers tanks up to two hundred feet in diameter. Above that, clause 4.3.3.4 requires the variable design point method.

The inputs

  • D, the nominal diameter, and H, the height from the bottom of the course to the maximum liquid level.
  • G, the highest specific gravity the tank stores, not only today’s product.
  • S, the allowable stress from Table 4.1 for the plate material. The bottom and second courses use a lower fraction of yield and tensile strength than the upper courses. When the material is unknown, clause 4.3.3.1 gives default yield and tensile values.
  • E, the original joint efficiency; Table 4.2 gives it when the records are gone. E may be taken as one when the thin spot is away from any weld by at least the greater of one inch or twice the plate thickness.

A whole course or a local thin area?

The note to clause 4.3.3 says the whole-course formula, with H to the bottom of each course, is the normal basis for judging the shell. For a locally thinned area, or a spot such as a new nozzle location, clause 4.3.3.1 b) uses H from the lowest point of the area to the liquid level, with no one-foot deduction.

Clause 4.3.2.1 sets how a corroded area of some size is measured: find the least thickness, work out the critical length L from the diameter and that thickness, and average at least five equally spaced readings along L in the worst vertical plane. The lowest average must be at least t-min, and the single least reading at least sixty percent of t-min, each plus any corrosion allowance needed to the next inspection (clause 4.3.2.1 e). Clause 4.3.2.2 lets widely scattered pits be ignored, but only if no pit leaves less than half of t-min (excluding corrosion allowance) and the pits along any vertical line stay within the limit of Figure 4.2.

What t-min does not cover

Clause 4.3.3.5 says these thickness checks cover liquid load only. Wind buckling, seismic load, service above two hundred degrees Fahrenheit, vacuum, loads from piping and tank-mounted equipment, overturning and settlement are evaluated separately, against the original construction standard.

When the shell does not meet t-min

Clause 4.3.1.5 gives three options: repair the area, lower the allowable liquid level, or retire the tank. To find a lower liquid level, solve the t-min formula for H using the measured thickness less the corrosion allowance; the maximum design liquid level is never exceeded. Clause 4.3.3.6 also allows a fitness-for-service evaluation under API 579-1/ASME FFS-1 or ASME Section VIII, Division 2, Appendix 4 design by analysis.

Working it out

The free shell t-min calculator runs clause 4.3.3.1 a) both ways: t-min from the course geometry, or the maximum fill height from a measured thickness. In TankForge, minimum thickness is calculated per course as the readings go in, citing its clause.

Also asked as

How is API 653 t-min calculated?

For a whole shell course, clause 4.3.3.1 a): a coefficient times the liquid height above the course bottom less one foot, times diameter and specific gravity, divided by allowable stress times joint efficiency, and never below a tenth of an inch. A local thin area uses clause 4.3.3.1 b), without the one-foot deduction.

What is the minimum acceptable shell thickness?

It is t-min from clause 4.3.3.1 for that course at its maximum liquid level and highest specific gravity, or the value from the variable design point method or a fitness-for-service evaluation where one of those governs.

How thin can a tank shell get?

For a corroded area, the average over the critical length must stay at or above t-min for the course at the current maximum fill height, and the single least reading at or above sixty percent of t-min (clause 4.3.2.1), with t-min never below a tenth of an inch. Short of that, the area is repaired, the fill height is lowered, the tank is retired, or a fitness-for-service evaluation justifies it.

TankForge is API 653 inspection software built by a working API 653 inspector. Draft report. Your certified inspector reviews and signs.