How do you calculate corrosion rate and remaining life on a storage tank?
API 653 clause 3.10 defines the corrosion rate as the total metal loss divided by the time over which it happened. Remaining life is the thickness left above the minimum (t-min for a shell course) divided by that rate.
On the shell, clauses 6.3.2.1 and 6.3.3.2 call the measured thickness minus the minimum required thickness RCA, and the shell corrosion rate N, and set the inspection intervals from RCA/N.
Shell: the arithmetic
- Rate = (earlier thickness − current thickness) ÷ years between the two readings, at the same location.
- RCA = current measured thickness − t-min for that course or location.
- Remaining life = RCA ÷ N, in years.
- External inspection by an authorized inspector: no longer than RCA/4N years (a quarter of the remaining life) or five years, whichever is less.
- External UT thickness readings: no longer than RCA/2N years (half the remaining life) or fifteen years, whichever is less; five years when the rate is not known.
Long-term or short-term rate?
API 653 does not print separate long-term and short-term formulas. Common practice works both: long-term from the nominal (or first recorded) thickness over the years in service, short-term from the last inspection to this one, and uses the faster of the two. A short-term rate much faster than the long-term one is a reason to look for a change in service or coating before trusting it, and a rate taken from two different spots is not a rate at all.
When there is no rate yet
Clause 6.3.3.2 a) sets a maximum UT interval of five years until a rate is known. A rate from a tank in similar service can be used; Annex H describes the similar service assessment.
Bottom: a different rule
The bottom does not use RCA/N. Clause 4.4.5.1 takes the soil-side rate as linear over the age of the tank, from the minimum remaining thickness after repairs, and takes it as zero for areas under effective cathodic protection; the product-side rate is zero under a coating whose life covers the interval. The rates and the minimum remaining thickness then set the next internal inspection under clause 6.4.2.2.1.
Working it out
The free shell corrosion rate calculator takes the current, previous and nominal readings and gives both rates, the remaining life and both external intervals. In TankForge, corrosion rate, remaining life and the next inspection interval are calculated as the readings go in, each citing its clause.
Also asked as
What is the API 653 corrosion rate formula?
Clause 3.10: total metal loss divided by the time over which it occurred. For a shell location that is the earlier thickness minus the current thickness, divided by the years between the readings.
How do you calculate tank remaining life?
Subtract the minimum required thickness from the current measured thickness to get the remaining corrosion allowance, then divide by the corrosion rate. The result is the remaining life in years.
Short-term vs long-term corrosion rate: which one governs?
API 653 does not say; it uses one shell corrosion rate. The common, conservative practice is to work both and use the faster one, after checking the short-term rate is not a measurement error.
TankForge is API 653 inspection software built by a working API 653 inspector. Draft report. Your certified inspector reviews and signs.