API 653 Table 4.2 / 4.3

Joint efficiency (Table 4.2 / 4.3) calculator

Shell joint efficiency E by construction standard and build-year edition band, welded or riveted.

For estimating and checking. The inspector of record is responsible for every number that goes into a report. Verify against the current edition of API 653 — this page was checked against API 653, 5th Edition, Addendum 2 (May 2020). Not a substitute for the standard or for engineering judgment.

Joint efficiency (E) knocks a construction quality factor into the t-min formula — a fully radiographed butt weld gets full credit, an old lap-welded or riveted joint gets much less. API 653 assigns E by the standard the tank was built to and, for most standards, the year it was built. Pick a standard and a build year below to see the row that applies, alongside the full table.

Leave blank to use the most recent edition band for the chosen standard (has no effect on Unknown standard or Riveted).

Butt — Basic Standard 1.00
Butt — Annex A, spot RT 0.85
Butt — Annex A, no RT 0.70
  1. Standard: API 650 — Seventh and later (1980–present)
StandardEditionJointApplicabilityE
API 650 *Seventh and later (1980–present)ButtBasic Standard1.00
API 650 *Seventh and later (1980–present)ButtAnnex A, spot RT0.85
API 650 *Seventh and later (1980–present)ButtAnnex A, no RT0.70
API 650Third to Sixth (1966–1978)ButtBasic Standard0.85
API 650Third to Sixth (1966–1978)ButtAnnexes D or G1.00
API 650First and Second (1961–1964)ButtBasic Standard0.85
API 650First and Second (1961–1964)ButtAnnex D1.00
API 12C14th and 15th (1957–1958)Butt—0.85
API 12CThird to 13th (1940–1956)Lap — full double3/8 in. (10 mm) max t0.75
API 12CThird to 13th (1940–1956)Butt—0.85
API 12CFirst and Second (1936–1939)Lap — full double7/16 in. (11 mm) max t0.70
API 12CFirst and Second (1936–1939)Lap — intermittent1/4 in. (6 mm) max t0.50
API 12CFirst and Second (1936–1939)Butt—0.85
Unknown standardWelded, code/edition unknownLap — full double7/16 in. (11 mm) max t0.70
Unknown standardWelded, code/edition unknownLap — intermittent1/4 in. (6 mm) max t0.50
Unknown standardWelded, code/edition unknownButt—0.70
Unknown standardWelded, code/edition unknownLap — single welded—0.35
RivetedTable 4.3 — within 6 in. (150 mm) of rivetsLap1 rivet row0.45
RivetedTable 4.3 — within 6 in. (150 mm) of rivetsLap2 rivet rows0.60
RivetedTable 4.3 — within 6 in. (150 mm) of rivetsLap3 rivet rows0.70
RivetedTable 4.3 — within 6 in. (150 mm) of rivetsLap4 rivet rows0.75
RivetedTable 4.3 — within 6 in. (150 mm) of rivetsButt2 rows/side0.75
RivetedTable 4.3 — within 6 in. (150 mm) of rivetsButt3 rows/side0.85
RivetedTable 4.3 — within 6 in. (150 mm) of rivetsButt4 rows/side0.90
RivetedTable 4.3 — within 6 in. (150 mm) of rivetsButt5 rows/side0.91
RivetedTable 4.3 — within 6 in. (150 mm) of rivetsButt6 rows/side0.92

The formula

E is read directly from Table 4.2a / 4.2b (welded) or Table 4.3 (riveted) by construction standard and build-year edition — there is no formula to compute; the calculator selects the right row.
SymbolMeaningUnitSource
EJoint efficiency used in the one-foot method / t-min formulaTable 4.2
API 653 Table 4.2API 653 Table 4.3

Worked example

Using the pre-filled example above (US customary units):

  1. Standard: API 650 — Seventh and later (1980–present)
  • Butt — Basic Standard: 1.00
  • Butt — Annex A, spot RT: 0.85
  • Butt — Annex A, no RT: 0.70

Where the inputs come from

  • Standard and build year come from the tank’s construction record, nameplate, or original design drawings — not a guess based on the tank’s apparent age.
  • When the construction record genuinely does not identify a standard or edition, the unknown-standard row is the conservative default API 653 assigns.
  • A riveted tank uses Table 4.3 instead of Table 4.2 — pick "Riveted" to see its joint efficiencies and its own flat allowable stress.

Built by TankForge — API 653 inspection software

TankForge keeps the shell layout’s joint efficiency wired to the Construction tab’s build year and standard, so a change to either one updates the other automatically instead of drifting out of sync.

Related

Frequently asked

Why does the same standard give a different E for a different build year?

API 653 groups editions of API 650 and API 12C into bands, because welding and inspection requirements changed as those standards were revised — an older edition band generally gets a lower joint efficiency for the same basic construction.

What is Annex A / spot RT vs no RT?

Annex A construction under the current API 650 editions can be built with or without spot radiographic testing (RT) of the welds. Spot RT earns a higher joint efficiency than the no-RT option in the same edition band.

My tank has no build year on record — what should I pick?

Leave the year blank to use the most recent (and, for a welded standard, most favorable) edition band, or switch the standard to "Unknown / not documented" if the construction standard itself is not known either — that is the most conservative starting point.

Does joint efficiency change over the life of the tank?

No — E is fixed by how the tank was originally built and does not change with age, corrosion, or repairs. A repair performed under a different code does not retroactively change the original shell’s E.

Is this the same E used for the shell t-min calculation?

Yes — this is the same joint efficiency the one-foot-method t-min formula uses. Enter it directly on the shell t-min calculator once you know it, or default to the Table 4.2 unknown-standard value if the construction record does not identify one.

Where to find labeled drawings

  • API 650 Annex H (internal floating roofs) and Annex C (external floating roofs): figures of the roof and its fittings.
  • API 653 Annex C checklists: the inspection names for most of these parts (C.1.4 roofs, C.1.5 roof accessories, C.2.8–C.2.9 floating roofs and seals).
  • EPA AP-42, Chapter 7.1 (Organic Liquid Storage Tanks): cutaway diagrams of guide poles, deck fittings, rim seals and vents, each part named. EPA AP-42 Chapter 7
  • Vendor catalogs for close-up photos: Enardo, Protectoseal, Groth, Varec, Shand & Jurs (vents, hatches, gauges); HMT, Matrix (floating roofs, seals).

Don’t see what you need?

Ask for a guide, calculator or tank part we haven’t covered. Email is optional — anonymous requests are welcome.